Smoke alarm, also known as fire smoke alarm, smoke sensor, etc. It is powered by the bus, and multiple buses can be connected to the bus to form an alarm system by networking and communicating with the fire alarm controller. There is no sound during the alarm, and the host has sound and light prompts. This type of smoke alarm device is generally called smoke detection. Device. Smoke detectors are divided into address codes and those without address codes.
The smoke alarm is composed of two parts: one is an inductive sensor for detecting smoke, and the other is an electronic speaker with a very loud sound, which can alert people in time if danger occurs. The smoke alarm uses the positive and negative ions generated by the ionization of the radioactive source americium to move toward the positive and negative electrodes under the action of the electric field. Under normal circumstances, the current and voltage of the internal and external ionization chambers are stable. Once smoke escapes outside the ionization chamber. Interfering with the normal movement of charged particles, the current and voltage will change, disrupting the balance between the internal and external ionization chambers, so the wireless transmitter sends out a wireless alarm signal to notify the remote receiving host to transmit the alarm information.
1. The smoke alarm is different according to the density of the measured gas, and the orientation of the indoor probe device is probably different. When the measured gas density is less than the air density, the probe should be installed 30cm away from the roof in the downward direction; otherwise, the probe should be installed 30cm above the ground in the upward direction.
2. The probe is mainly a detection element that touches the incineration gas sensor. It is composed of a platinum wire coil coated with alumina and a binder, and its outer surface is attached with platinum, palladium and other metals. Therefore, be careful when installing the device to prevent the probe from being damaged.
3. The device of the open-air probe can choose the height of the device according to the density of the measured gas. Special attention should be paid that the probe should be installed on the disadvantaged side.
4. After commissioning the device, a breathable waterproof cover must be installed to prevent rain from entering the damaged probe.
5. There must be no strong electromagnetic fields (such as high-power motors and transformers) affecting the appearance of the smoke alarm.
6. The smoke alarm is external in appearance and has the function of sound and light. It should be installed in the place where the operator can easily see and hear in order to eliminate hidden dangers in time.
7. The height of the gas detector should normally be 160-170cm, so that the maintenance personnel can carry out normal maintenance.
8. Maintenance sleeves should be added to the connecting cables, and metal hoses should be added at the connection points of the probe, and pay attention to the explosion-proof grade of the factory.
संपर्क करें

Author:

Ms. Zoe

Phone/WhatsApp:

+8613246310600

लोकप्रिय उत्पाद
You may also like
Related Categories

इस आपूर्तिकर्ता को ईमेल

विषय:
मोबाइल फोन:
ईमेल:
संदेश:

Your message must be betwwen 20-8000 characters

होम

Product

Shopcart

हमारे बारे में

जांच

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

भेजें

Manage Your Cookies

Necessary cookies are always enabled. You can turn off other cookie options. Cookie Policy and Privacy Policy.

To use chat support services, please enable support cookies.

Strictly Required Cookies

Off

These cookies are required for the website to run and cannot be switched off. Such cookies are only set in response to actions made by you such as language, currency, login session, privacy preferences. You can set your browser to block these cookies but this might affect the way our site is working.

Analytics and Statistics

Off

These cookies allow us to measure visitors traffic and see traffic sources by collecting information in data sets. They also help us understand which products and actions are more popular than others.

Marketing and Retargeting

Off

These cookies are usually set by our marketing and advertising partners. They may be used by them to build a profile of your interest and later show you relevant ads. If you do not allow these cookies you will not experience targeted ads for your interests.

Functional Cookies

Off

These cookies enable our website to offer additional functions and personal settings. They can be set by us or by third-party service providers that we have placed on our pages. If you do not allow these cookies, these or some of these services may not work properly
CLOSE ACCEPT SELECTED COOKIES

We've updated our Terms of Service and Privasy Policy, to better explain our service and make it more understandable. By continuing to see this site, you agree to our updated Terms of Service and Privacy Policy. We use cookies to improve and personalize your browsing experience. By clicking "Accept Ceokies", you accept our use of cookies in accordance with our Cookie Policy.